Three Phase Protection Relay Test Set Secondary Current Injector Tester 3 Phase Relay Tester

Product Details
Customization: Available
Type: Universal Testing Machine
Maxcapacity: <1000KN
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2005-03-17
Management System Certification
ISO9001:2015
  • Three Phase Protection Relay Test Set Secondary Current Injector Tester 3 Phase Relay Tester
  • Three Phase Protection Relay Test Set Secondary Current Injector Tester 3 Phase Relay Tester
  • Three Phase Protection Relay Test Set Secondary Current Injector Tester 3 Phase Relay Tester
  • Three Phase Protection Relay Test Set Secondary Current Injector Tester 3 Phase Relay Tester
  • Three Phase Protection Relay Test Set Secondary Current Injector Tester 3 Phase Relay Tester
  • Three Phase Protection Relay Test Set Secondary Current Injector Tester 3 Phase Relay Tester
Find Similar Products

Basic Info.

Model NO.
SXJB
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
LCD
Control
Computer Control
Power Source
AC 110V/220V at Customized
Oil Cylinder Position
Under
Test Phase
Six 6 Phase
Time Measuring Range
1ms~9999s
Power Supply
AC220V±10%, 50Hz
Transport Package
Plywood Case
Specification
ISO9001 SGS
Trademark
Sansion
Origin
Wuhan, China
HS Code
9030899090
Production Capacity
100 Units

Product Description

Three Phase Protection Relay Test Set Secondary Current Injector Tester 3 Phase Relay Tester
Three Phase Protection Relay Test Set Secondary Current Injector Tester 3 Phase Relay Tester
Three Phase Protection Relay Test Set Secondary Current Injector Tester 3 Phase Relay Tester


General information:

Protection systems play a key role for the safe and reliable operation of today's electricity power systems. Properly working protection devices help to maintain the safety of the system and to safeguard assets from damage. SXJB-6600 Protection Relay Tester is the essential test tool for relay protection technicians.

Features:

√ To meet all the test requirements. 6 phase current and 6 phase voltage output simultaneously. Current 30A/phase, voltage 125V/phase.  6 phase current paralleled can reached to 180A. It's not only can test on traditional relays and protection devices, but also can test on various microcomputer protection, especially better test for transformer differential protection and automatic bus transfer device.

√ Can run independently, high performance IPC, CPU 300--600MHz, RAM 128M, HDD 6-12G, Window XP system. It also can be outside connected with computer.

√ Stainless steel panel and keyboard, touch type mouse.

√ 8.4 inch TFT true color screen.

√ High fidelity linear power amplifier, to ensure small current's precision, and large current's stability.

√ USB port, to connect with PC directly.

√ To be connected with laptop easily.

√ GPS synchronous test function. Build-in GPS card (option), to be connected with PC via RS232 port. To realize two testers can test synchronously even at the different site.

√ Equipped with independent special auxiliary DC voltage source, output voltage is 110V (1A), 220V (0.6A). To provide DC working power supply for relay or protection devices.

√ Self calibration. 


Specifications:
AC power source:
 
 
 
 
 
 
 
Amplitude range:      6×(0-30A)
Precision:0.2%
6 phase current paralleled max. output:: 180A
Phase current long term allowable working value: 10A
Power:  450VA/phase
6 phase paralleled max. power: 1000VA
6 phase paralleled allowable max. output duty: 10s
Frequency range:0--1000Hz
Accuracy:0.001Hz
Harmonic order: 2-20 times
Phase position: 0--360°; Precision:0.1°
DC voltage source:
 
Amplitude:30A/phase
Power: 300VA/phase; Accuracy: 0.2%
AC voltage source:
 
 
 
 
 
Amplitude range :6 ×(0--125V);  Precision: 0.2%
Line voltage range: 0--250V
Phase voltage/Line voltage output power: 80VA/100VA
Frequency range: 0--1000Hz; Precision: 0.001Hz
Harmonic order:  2-20 times
DC voltage source:
 
 
 
Phase voltage output amplitude:0--±150V;   Precision:0.2%
Line voltage output amplitude:0--±300V; 
Phase voltage/Line voltage output power:90VA/180VA
Switching value terminal::
 
 
 
                
 
 
Switching value input terminal: 8 pairs
Idle contact: 1--20mA,24V inner source
Potential switching:0--6VDC is low level
15--250VDCis high level
Switching value output terminal: 4 pairs
Idle contact, interrupting capacity:110V/2A,220V/1A
Time measuring range: Range: 1ms~9999s;    Precision: 0.1ms
Power supply: AC220V±10%, 50Hz  10A

Warranty: One year quality guarantee after shipment.


More information, please kindly contact with us, we can recommend the suitable test set according your requirements and give you the best quotation. Thank you!   
Three Phase Protection Relay Test Set Secondary Current Injector Tester 3 Phase Relay Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier