• Underground Cable Fault Pinpointing Tester
  • Underground Cable Fault Pinpointing Tester
  • Underground Cable Fault Pinpointing Tester

Underground Cable Fault Pinpointing Tester

Connectors: USB
Test Mode: Saved Test
Usage: Power Cable
Test Region: Forming Cable
Cable Type: Shielded
Power: Electricity
Customization:

Contact Supplier

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SXDL-330A
Customized
Customized
Color
Black
Test Distance
40km
Test Voltage
0-35kv
Weight
3kg
Transport Package
Plywood
Specification
ISO9001 SGS
Trademark
Sansion
Origin
Wuhan, China
HS Code
9030899090
Production Capacity
100 Units

Product Description

General Information:
SXDL-330 is applied for detecting the different cable faults including: low impedance, short circuit, open circuit broken fault, high impedance leakage and high impedance flash over fault. It's suitable for various 35KV and below copper aluminum core power cables, coaxial telecommunication cable, and local cable.
The system is including:
  1. SXDL-330S Cable Fault TesterSXDL-330D Cable Fault LocatorSXDL-330L Route TracerPulse capacitorOther accessories

Features:
Large LCD screen.Measuring mode: Low voltage pulse, impulse high voltage current sampling, DC high voltage flash over and etc.High performance rechargeable battery, USB sampling port, could connect with laptop directly.HV is fully isolated against operator and instrument, high anti-interference ability and safe reliability. The distance from test to failure location can be displayed directly.Build in printer, test results and waveform can be stored automatically.Full English interface, to display the test waveform clearly.Windows system, easy to operate.Double waveform track tracers, easy to compare and analyze the waveforms. 
SXDL-330S Cable Fault Tester

Specification:
Test distance:
 
4m~40km
Test precision: Error is no more than 1m @ measuring range < 1km.
Relative error is no more than 0.5% @ measuring range > 1 km.
Pulse amplitude: no less than 250V @ 50Ω
Pulse width:  0.2μs, 2μs, 4μs
Sampling frequency: 48MHz, 24MHz, 12MHz, 6MHz
System Error: 10cm
Reading Frequency:
 
V/2f V is the electric wave's propagation velocity  in the cable (m/μs). f is sampling frequency (MHz). For example the oil-paper cable's propagation velocity is V=160m/μs, f=40MHz sampling, the reading frequency is 160/(2×40)=2m.
Presetting 5 types electric wave's propagation velocity of cable medium: Oil-paper: 160m/μs
XLPE: 172m/μs
PVC: 184m/μs
Rubber Cables for Coal Mine: 100m/μs
Others non-power cable's propagation velocity of electric wave are settable. (Medium is at user's option)
Sampling: Current sampling method.
Power Supply: Power frequency or build-in rechargeable battery.
Power frequency: AC 220V±10%, frequency 50Hz±5%, 24 hours continuously working.
Battery: 4 hours continuously working.
Working temperature: -10ºC~50ºC
Oversize: (L×W×H)  330×230×150mm
Weight: 3kg.

SXDL-330D Digital Cable Fault Locator
It's used to locate the power cable insulated fault point, route, depth accurately.Features: High pointing sensitivity. Digital displaying the distance between the faults locating and sensor probe.To touch the sensor probe on fault cable or its near cable, the fault distance and direction could be displayed accurately. Easy to operate.Compact designation, portable. Specification:
Digital display distance: Max. 500m, Min. 0.1m.
Rough test error: is less than 10%, locating error is 0.
Electromagnetic channel gain: >110dB (300 thousand times)
Electromagnetic channel receiver sensitivity: <5μV
Audio channel frequency amplifier gain:
 
120dB  1 million times when SNR (Signal to Noise Ratio) is @ 4:1.
50Hz power frequency inhibition degree >40dB (100 times)  
Audio & electric synchronous display: when do the locating test on site , the digital screen to repeat counting one time under the shocking of electromagnetic which formed by pulse high voltage. And to display the fault distance or fully lighted (500m). The high impedance earphone could detect the seismic wave generated by impulsive discharging breakdown.
To change the sound wave sensor probe to the 15KHz electromagnetic one, it could be used as accurate cable route and depth detecting test.
Power supply: 6V maintenance-free battery 1.2AH.
Power consumption: <120mA (0.7W)
Working temperature: -10ºC~+50ºC RH 80%.
Please contact us by email for further information.

Warranty: One year quality guarantee after shipment.
More details please kindly contact with Sansion Power.Thank you!   
Underground Cable Fault Pinpointing Tester



 

Send your message to this supplier

*From:
*To:
avatar Ms. Kelly Pan
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2005-03-17
Management System Certification
ISO9001:2015