40kv Vlf Test Set for 6kv-10kv XLPE Cables of Preventive Tests at The Jobsite

Product Details
Customization: Available
Usage: Power Cable
Power: Electricity
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2005-03-17
Management System Certification
ISO9001:2015
  • 40kv Vlf Test Set for 6kv-10kv XLPE Cables of Preventive Tests at The Jobsite
  • 40kv Vlf Test Set for 6kv-10kv XLPE Cables of Preventive Tests at The Jobsite
  • 40kv Vlf Test Set for 6kv-10kv XLPE Cables of Preventive Tests at The Jobsite
  • 40kv Vlf Test Set for 6kv-10kv XLPE Cables of Preventive Tests at The Jobsite
  • 40kv Vlf Test Set for 6kv-10kv XLPE Cables of Preventive Tests at The Jobsite
  • 40kv Vlf Test Set for 6kv-10kv XLPE Cables of Preventive Tests at The Jobsite
Find Similar Products

Basic Info.

Model NO.
SXVLF
Certification
CE
Customized
Customized
Color
Black
Test Voltage Range
30kv/40kv/50kv/60kv/70kv/80kv/90kv
Output Frequency
0.1Hz,0.05Hz,0.02Hz
Model
Sxvlf
Accuracy
3%
Transport Package
Plywood Case
Specification
ISO9001 SGS
Trademark
Sansion
Origin
Wuhan, China
HS Code
9030339000
Production Capacity
100 Units

Product Description

40kv Vlf Test Set for 6kv-10kv XLPE Cables of Preventive Tests at The Jobsite
40kv Vlf Test Set for 6kv-10kv XLPE Cables of Preventive Tests at The Jobsite

General information:

VLF Test Sets from 30kV - 90kV with Sine Wave Output

VLF means 'Very Low Frequency' is used in AC hipot test for power cables, transformers, switchgear and other electrical apparatus.

A VLF hipot is just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 50/60Hz. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, rather than 60Hz, it takes 600 times less current and power to apply an AC voltage to a capacitive load, like a long cable.

VLF (Very Low Frequency) Testers are suitable for testing power cables, transformers, switchgear, rotating machinery and other electrical apparatus.

Features:

√  Adapts microprocessor controlled, can realize voltage set-up/down, measuring and protecting automatically. Manual intervention is allowable even during the auto voltage boosting.

√   Portable, easy to move.

√   Large LCD can display waveform clearly, and test report can be printed by built-in printer.

√   The data of current, voltage, and waveform can be sampled at HV side.

√   Over voltage protection: When the output is beyond the limitation, the control unit will shut itself down within 20ms.

√   Over current protection: high & low voltage double protection, the precision value of power off protection can be setting at HV side. When the current of LV side is exceeded rated, the control unit will shut itself down within 20ms.

√   HV output protection resistor is built in the booster, not need to connect outside resistor.

√   Adapting high & low voltage closed loop negative feedback control circuit, there is no capacitive rise effect during the output.
40kv Vlf Test Set for 6kv-10kv XLPE Cables of Preventive Tests at The Jobsite

Specifications:

Model Output Voltage/Current
(Peak)
Load Capacity Fuse Control Unit Booster
Net Dim.
(cm)
Net Wt
(kg)
Net Dim.
(cm)
Net Wt
(kg)
SXVLF-30/1.1 30KV/29mA 0.1Hz ≤ 1.1uF 8A 28×37×22 4 33×18×34 25
0.05Hz ≤ 2.2uF
0.02Hz ≤ 5.5uF
SXVLF-40/1.1 40KV/29mA 0.1Hz ≤ 1.1uF  
8A
 
28×37×22 4 35×20×36 45
0.05Hz ≤ 2.2uF
0.02Hz ≤ 5.5uF
SXVLF-50/1.1 50KV/59mA 0.1Hz ≤ 1.1uF  
10A
 
28×37×22 4 37×24×39 45
0.05Hz ≤ 2.2uF
0.02Hz ≤ 5.5uF
SXVLF-60/0.5 60KV/59mA 0.1Hz ≤ 0.5uF  
20A
 
28×37×22 4 33×18×34
33×18×34
25+45
0.05Hz ≤ 1.0uF
0.02Hz ≤ 2.5uF
SXVLF-70/0.5 70KV/59mA 0.1 Hz, ≤0.5µF  
20A
 
28×37×22 4 33×18×34
35×20×36
25+45
0.05Hz, ≤1.0µF
0.02Hz, ≤2.5µF
SXVLF-80/0.5 80KV/59mA 0.1 Hz, ≤0.5µF 20A 28×37×22 4 33×18×34
37×24×39
25+45
0.05Hz, ≤1.0µF
0.02Hz, ≤2.5µF
SXVLF-90/0.5 90KV/59mA 0.1 Hz, ≤0.5µF  
20A
 
28×37×22 4 33×20×35
37×24×39
30+45
0.05Hz, ≤1.0µF
0.02Hz, ≤2.5µF
 

√   Accuracy: 3%                                  

√   Voltage +/- peak value error: ≤3%

√   Voltage waveform distortion: ≤5%

√   Working temperature: -10ºC+40ºC
√   Working humidity: ≤85%RH