Capacitance Impulse Current Generator Power Testing System Long Life

Max Diameter of Workpiece: 900mm
Mass Scope of Workpiece: <900kg
Type: Impact Testing Machine
Maxcapacity: >1000KN
Accuracy Grade: 0.5
Load Way: Electronic Load
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SXCF
Loading Method
Static Load
Display
LCD
Control
Computer Control
Weight
100-500Kg
Power Source
AC 110V/220V at Customized
Oil Cylinder Position
Under
AC Withstand Test for
0~220kv
Max. Capacity
2000kVA
Output Frequency
45 - 300Hz
Waveform
Pure Sine Wave
Frequency Adjustment Sensitivity
0.01Hz
Transport Package
Plywood Case
Specification
ISO9001 SGS
Trademark
Sansion
Origin
Wuhan, China
HS Code
9030339000
Production Capacity
100 Units

Product Description

Capacitance impulse current generator Power Testing System Long Life

System instruction Main Parameters for System

  • Nominal voltage: ±200kV
  • Rated stage voltage: ±100kV
  • Rated energy: 10kJ
  • Impulse capacitance: 0.5µF
  • Number of stages: 2
  • Rated stage capacitance: 1µF(each impulse capacitor 1µF at 100kV, total 2pcs)
  • Impulse voltage waveform: generated when load capacitance is 300-3000pF.

T1=1.2µs±30%, T2=50µs±20%, standard lightning impulse voltage full waveform of peak voltage deviation≤3%;

Standard operation waveform 250±20%/2500±60%. These 2 Impulse voltage waveform parameters and error are accorded with national requirements of IEC standard.

  • Voltage utilization factor: Standard lightning impulse voltage waveform ≥90% when load capacitance is below 1000pF, standard operation impulse voltage waveform≥80% when load capacitance is below 2000pF. Standard operation impulse voltage waveform ≥70%.
  • Locking range: level voltage is within the range of 20%-100% rated voltage, positive and negative locking range no less than 25%.
  • Out-of-control rate of synchronous discharge: <5%
  • Min. output voltage: ≥±20% of rated voltage.
  • Instability of discharge voltage: <±1.0%
  • Continuous time: Above 2/3 of rated voltage, continuous working when charge and discharge once every 120s. Below 2/3 of rated voltage, continuous working when charge and discharge once every 60s.


Capacitance Impulse Current Generator Power Testing System Long Life

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2005-03-17
Management System Certification
ISO9001:2015