High Precision Resistance Meter Calibrator

Maximum Output: 200g Ohm
Type: Universal Testing Machine
Maxcapacity: <1000kn
Accuracy Grade: 0.5
Load Way: Electronic Load
Loading Method: Dynamic Load
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SXGZ-A
Display
Digital
Control
Manual Control
Weight
0-100kg
Power Source
AC 110V/220V at Customized
Transport Package
Carton or Plywood
Specification
ISO9001 SGS
Trademark
Sansion
Origin
Wuhan, China
HS Code
9030332000
Production Capacity
100 Units

Product Description

High Precision Resistance Meter Calibrator

General information:

SXGZ-A Insulation Resistance Meter Calibrator is the reference instrument to calibrate insulation resistance meter. The output maximum limitation is 200GΩ, nominal working voltage is 5kV. It's suitable for all models pointer type insulation resistance meter. 

Features:
√  Designed with independent leakage shield terminal and ground terminal, no obvious unstable, short circuit and open circuit.
√  High performance switch, long life service.
√  The open circuit voltage, mid-value voltage and peak value voltage are all measurable.
√  LCD screen
√  Long service life HV switchgear. 

Specifications:

Resistance output (HV Hi-Resistance Box)

√ Accuracy degree and working voltage (current)

Resistance Value

100GΩ

×10GΩ

×1GΩ

×100MΩ

×10MΩ

×1MΩ

Accuracy Degree

5

5

2

1

0.5

0.2

Nominal Voltage

5000V

5000V

5000V

5000V

2500V

1000V

 

Resistance Value

×100kΩ

×10kΩ

×1kΩ

×100Ω

Accuracy Degree

0.2

0.2

0.2

0.2

Nominal Current

1mA

8mA

20mA

50mA

√ Adjusting range: 100Ω~200GΩ, adjusting fineness: 100Ω

√ Working Condition:

   Reference temperature range:  20~25ºC

   Nominal working temperate range: 18~28ºC

   Reference humidity range:  40%~60%

   Nominal working temperature range:  25%~70%

   Resistance variation limitation:

Influence

Nominal working range

Allowed variation

Environmental Temperature

18~28ºC

a/2 %

Relative Humidity

25%~70%

≤10GΩ a/2 % >10GΩ a%

Working Voltage

(1~1/5)nominal voltage

≤10GΩ a/2 % >10GΩ a%

 

Note: "a" is the accuracy degree of output resistance meter.(a's value is according to different resistance meter)

√ Insulation Resistance:

   The resistance value measured under nominal voltage is no less than 5TΩ, this value is the insulation resistance between output circuit and the circuit without any electric connection.

√  Dielectric strength: Between resistance output circuit with test point, the withstand ability is sine frequency 45~65Hz AC 11kV, test 1 min, no breakdown and flashover.

√  Residual resistance of input terminal should be <0.1Ω, variation <0.01Ω.

√  Oversize: 442mm×270mm×145mm

√  Weight: <5kg
 

Voltage measuring (HV DC Digital Voltmeter):

√  Measuring range:  0~5000V

√  Accuracy:  ±(1 % read ±1 digit)

√  Power Supply:  DC9V

√  Input resistance:  ≥10GΩ

Warranty: One year quality guarantee after shipment.


More information, please kindly contact with us, we can customize the suitable test set according your requirements and give you the best quotation. Thank you! 
High Precision Resistance Meter Calibrator
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2005-03-17
Management System Certification
ISO9001:2015