• Transformer No Load Loss Test Automatic Transformer Test Bench
  • Transformer No Load Loss Test Automatic Transformer Test Bench
  • Transformer No Load Loss Test Automatic Transformer Test Bench
  • Transformer No Load Loss Test Automatic Transformer Test Bench
  • Transformer No Load Loss Test Automatic Transformer Test Bench
  • Transformer No Load Loss Test Automatic Transformer Test Bench

Transformer No Load Loss Test Automatic Transformer Test Bench

Max Diameter of Workpiece: 900mm
Mass Scope of Workpiece: <900kg
Type: Strength Testing Machine
Maxcapacity: >1000KN
Accuracy Grade: 0.5
Load Way: Electronic Load
Customization:

Contact Supplier

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SXBZ
Loading Method
Static Load
Display
LCD
Control
Computer Control
Weight
0-100Kg
Capacity
10kVA~50000kVA or Customized
Operation Interface
Fully English Interface
Test Item
No Load, DC, Insulation, Heat Run, Power Frequency
Control Mode
Auto & Manual
Test Items
Turn Ratio, DC Winding, Noload Loss Load Impedance
Transport Package
Plywood Case
Specification
ISO9001 SGS
Trademark
Sansion
Origin
Wuhan, China
HS Code
9030841000
Production Capacity
100 Units

Product Description

Transformer No Load Loss Test Automatic Transformer Test System Equipment

General Information:

A complete line of Transformer Test Systems, from a small portable unit with a rating of 5kVA to power transformer Testing Systems capable of testing transformers with very high voltage and power ratings can be supplied. The line includes both single and three phase system for both distribution and power transformers. It's widely used in the fields of power supply and distribution, power transformer manufacturer, transformer maintenance center, industry and mining enterprises.
 
Features
  • Sansion Transformer Test System will perform tests in accordance with IEC 60076 and IEEE C57 serial latest edition standards.
  • Applied for different voltage degree transformers, reactors and HV switchgears.
  • Fully PLC controlling and measurement, integrated primary wire connection circuit displaying, measuring, control tracing, analysis processing, report storing, printing and protecting into the testing system.
  • All the test data calculation was operated by IPC, the test results and measuring data are displayed in screen directly which highly improved the precision and efficiency.
  • The test system could be customized to bench type, microcomputer type or any at user's option to be suitable for your test site.
 
Test Items:
Routine tests:
  • Transformer oil testing (including acidity, dewpoint, flashpoint, breakdown, capacitance &tan delta, dissolved gas analysis)
  • Transformer insulation resistance testing
  • Transformer winding resistance testing
  • Transformer turns ratio testing
  • Transformer load/no-load current & loss testing
  • Transformer capacitance & tan delta testing
  • Transformer short circuit impedance & load loss testing
  • Transformer power frequency withstand voltage testing
  • Transformer inductive withstand voltage testing (including 110kV transformer partial discharge testing)
  • Impulse voltage testing (including full wave, chopping wave testing)
 Type tests:
  • Temperature rising testing
 Special tests:
  • Zero-sequence impedance testing
Please contact SansionPower for further information.
Transformer No Load Loss Test Automatic Transformer Test Bench








 

Send your message to this supplier

*From:
*To:
avatar Ms. Kelly Pan
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2005-03-17
Management System Certification
ISO9001:2015